1.
Chinese Journal of Otorhinolaryngology Head and Neck Surgery ; (12): 672-680, 2023.
Artigo em Chinês | WPRIM | ID: wpr-986944

RESUMO

Objective: This study was to investigate the main characteristics and related factors of wideband absorbance (WBA) in children with normal hearing and to obtain age-specific reference range of WBA. Methods: 384 children between 0-12 years old (615 ears) who visited the Beijing Children's Hospital, Capital Medical University from October 2019 to February 2021 were enrolled, including 230 males (376 ears) and 154 females (239 ears), with totally 306 left ears and 309 right ears. Wideband tympanometry (WBT) was performed and normative WBA data were analyzed by SPSS 24.0 statistical software. Repeated measures and multivariate analysis of variance were applied to the data from 16 points at 1/3-octave frequencies (226, 324, 408, 500, 667, 841, 1 000, 1 297, 1 682, 2 000, 2 670, 3 364, 4 000, 5 339, 6 727 and 8 000 Hz) to evaluate the effects of frequency, age, external auditory canal pressures, gender and ear on WBA. Results: According to the WBT frequency-absorbance curve, the subjects were divided into seven groups: 1-month old group, 2-month old group, 3-month old group, 4-5 month old group, 6-24 month old group,>2-6 year old group and>6-12 year old group. The WBA of normal-hearing children underwent a series of developmental changes with age at both ambient pressure and tympanometric peak pressures. WBA results for 1-month group and 2-month old group exhibited a multipeaked pattern, with the peaks occurring around 2 000 and 4 897 Hz, and a notch around 3 886 Hz. WBA results for 3-month group and 4-5 month old group exhibited a single broad-peaked pattern, with the peak occurring between 2 000-4 757 Hz. The WBA of 1-month old group to 4-5 month old group decreased gradually at low frequency (226-408 Hz) and 6 727 Hz, and increased at middle to high frequency (2 670-4 000 Hz). The WBA of 6-24 month old group were significantly lower than that of 2-month old group to 4-5 month old group at all frequencies except 3 364 and 4 000 Hz. WBA results for 6-24 month old group,>2-6 year old group and>6-12 year old group exhibited a single-peaked pattern, and the peak frequency of WBA moved to the lower frequency successively. From 6-24 month old group to>6-12 year old group, the WBA gradually increased at low to middle frequencies (667-2 670 Hz) and 8 000 Hz, and decreased at middle to high frequencies (3 364-5 339 Hz). Among the 16 frequencies of all age groups, the difference between WBA under ambient pressure and tympanometric peak pressure were -0.09-0.06, and 43.75%-81.25% frequency points had statistically significant difference, which was mainly manifested in that WBA under ambient pressure were lower than that under tympanometric peak pressure at 226-1 682 Hz. There was no significant ear effect on all of the age groups. Similarly, there was no significant gender effect except for 3-month old group and 4-5 month old group. Conclusions: The WBA of normal-hearing children measured at ambient pressure and tympanometric peak pressure varied across the frequencies with age from 1 month to 12 years old, and different frequencies followed different change patterns (increase vs. decrease) in WBA. There was also significant external auditory canal pressures effect on all of the age groups. The establishment of age-specific reference range of WBA for 0-12 years old normal-hearing children in this study would be useful for clinical practice of determining normative data regarding WBT.


Assuntos
Masculino , Feminino , Humanos , Criança , Recém-Nascido , Lactente , Pré-Escolar , Estudos Transversais , Testes de Impedância Acústica/métodos , Orelha , Valores de Referência , Meato Acústico Externo
2.
Braz. j. otorhinolaryngol. (Impr.) ; 85(2): 193-198, Mar.-Apr. 2019. graf
Artigo em Inglês | LILACS | ID: biblio-1001557

RESUMO

Abstract Introduction: Tympanometry is currently the most frequently used tool for assessing the status of the middle ear, commonly assessed using a single 226 Hz tone. However, the use of the Acoustic Immittance Measures with a wideband stimulus is a promising high-resolution evaluation, especially in individuals known to have middle ear alterations, such as Down syndrome patients. Objective: The aim of this study was to analyze the acoustic absorbance measurements in children with Down syndrome. Methods: Cross-sectional study, approved by the institution's ethics committee. Data were collected from 30 children, with a mean age of 8.4 years, 15 with Down syndrome (DS-study group) and 15 children with typical development and no hearing complaints (control group). Energy absorbance was measured at frequencies of 226-8000 Hz at ambient pressure and at peak pressure as a function of frequency using TITAN equipment. Statistical analysis was performed using the established level of statistical significance of 5%. Results: With the 226 Hz probe tone, 30 ears of the control group and 22 of the study group exhibited Type A tympanograms, whereas Type B was observed in eight children in the study group. The mean acoustic absorbance ratio of the study group was lower than that of the control group at frequencies centered at 2520 Hz (p = 0.008) for those with normal tympanometry results, and 226-4000 Hz (p < 0.03) for those with a Type B tympanometry curve. Conclusion: The low energy absorption in the presence of normal tympanograms in children with Down syndrome may suggest middle ear abnormalities.


Resumo Introdução: A timpanometria é a ferramenta mais usada para avaliar o status da orelha média, comumente avaliada por meio de uma única frequência com o tom de 226 Hz. No entanto, o uso da medida de imitância acústica com estímulo de banda larga é uma avaliação de alta resolução promissora, especialmente em pacientes conhecidos por frequentemente apresentar alterações da orelha média, como na síndrome de Down. Objetivo: Analisar as medidas de absorvância acústica em crianças com síndrome de Down. Método: Estudo transversal, aprovado pelo comitê de ética da instituição. Foram coletados dados de 30 crianças, com idade média de 8,4 anos, sendo 15 com síndrome de Down (SD-grupo de estudo) e 15 crianças desenvolvimento típico e sem queixas auditivas (grupo controle). A absorvância de energia foi medida nas frequências de 226-8.000 Hz à pressão ambiente e no pico de pressão em função da frequência, usou-se o equipamento Titan. A análise estatística foi feita com o nível de significância estatística adotado de 5%. Resultados: Com o tom de sonda de 226 Hz foram observadas 30 orelhas do grupo controle e 22 do grupo estudo com timpanometria Tipo A e o Tipo B foi observado apenas em oito crianças do grupo estudo. A razão média de absorvância acústica do grupo estudo foi menor do que a do controle nas frequências centradas em 2.520 Hz (p = 0,008) para aqueles com resultados timpanométricos normais e de 226-4.000 Hz (p < 0,03) para aqueles com curva timpanométrica Tipo B. Conclusão: A baixa absorção de energia na presença de timpanogramas normais nas crianças com síndrome de Down pode sugerir anormalidades na orelha média.


Assuntos
Humanos , Masculino , Feminino , Criança , Testes de Impedância Acústica/métodos , Síndrome de Down/fisiopatologia , Orelha Média/fisiopatologia , Valores de Referência , Estudos de Casos e Controles , Estudos Transversais , Estatísticas não Paramétricas , Otopatias/diagnóstico , Otopatias/fisiopatologia
3.
Bauru; s.n; 2017. 85 p. ilus, tab, graf.
Tese em Português | LILACS | ID: biblio-880703

RESUMO

Na prática clínica, nota-se uma dificuldade em identificar a rigidez do sistema tímpano-ossicular decorrente da Otosclerose por meio dos métodos de avaliação rotineiramente empregados. Assim, as medidas de imitância acústica de banda larga podem fornecer mais informações sobre a condição do sistema tímpano-ossicular por avaliarem uma ampla faixa de frequência. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em indivíduos com diagnóstico de Otosclerose submetidos à estapedectomia ou estapedotomia. Foram avaliados 40 indivíduos na faixa etária de 33 a 80 anos, totalizando 54 orelhas operadas e 22 orelhas não operadas. A avaliação audiológica foi realizada por meio da otoscopia, audiometria tonal liminar, logoaudiometria e imitanciometria. As medidas de imitância acústica de banda larga foram obtidas por meio do sistema de medidas Middle-Ear Power Analyzer MEPA3, versão 5.0 (Mimosa Acoustics), utilizando os estímulos tom puro e chirp. Os dados obtidos foram submetidos à análise estatística descritiva e inferencial, com nível de significância de 0,05. As orelhas com Otosclerose apresentaram maior absorvância em 750 Hz, uma tênue diminuição até 3000 Hz, acentuando-se a partir desta frequência. A magnitude da admitância foi maior na faixa de frequência de 1992 a 4008 Hz, assim como a magnitude da impedância foi maior nas frequências baixas com diminuição até 4008 Hz e aumento em 6000 Hz. Estas orelhas foram dominadas pela rigidez nos sons graves e médios, por resistência entre 3000 e 4008 Hz e a partir desta frequência pela massa. A fase da impedância foi maior em 258 Hz e o delay da reflectância (slope) apresentou uma variação de comportamento entre as frequências, não sendo possível caracterizar um padrão de resposta. Conclui-se que há diferenças nas medidas obtidas nas orelhas com Otosclerose submetidas à cirurgia, quando analisadas as frequências baixas e médias, o que demonstra o impacto positivo da intervenção cirúrgica na funcionalidade do sistema tímpano-ossicular.(AU)


In clinical practice, there is a difficulty in identifying the rigidity of the tympano-ossicular system resulting from Otosclerosis through the routinely employed evaluation methods. Thus, wideband acoustic immitance measurements can provide more information on the condition of the tympanic-ossicle system by evaluating a wide frequency range. This study aimed at characterizing the wideband acoustic immitance measurements with the pure tone and chirp stimuli in individuals diagnosed with Otosclerosis submitted to stapedectomy or stapedotomy. Forty individuals aged 33 to 80 years were evaluated, totaling 54 operated and 22 non-operated ears. Audiology assessment was performed through otoscopy, pure-tone audiometry, logoaudiometry and imitanciometry. Wideband acoustic immitance measurements were obtained using the Middle-Ear Power Analyzer (MEPA3), version 5.0 (Mimosa Acoustics), by means of pure tone and chirp stimuli. Data were submitted to descriptive and inferential statistical analysis, with a significance level of 0.05. The ears with Otosclerosis presented a greater absorbance in 750 Hz, a slight diminution until 3000 Hz, being accentuated from this frequency. The admittance magnitude was higher in the frequency range from 1992 to 4008 Hz, as well as the impedance magnitude was higher in the low frequencies with a decrease up to 4008 Hz and an increase in 6000 Hz. These ears were dominated by rigidity in the low and medium sounds, by resistance between 3000 and 4008 Hz, and from this frequency, by the mass. The impedance phase was higher at 258 Hz and the reflectance delay (slope) showed a behavioral variation between the frequencies, a response not being characterized. It can be concluded that there are differences in the measurements obtained in Otosclerosis ears submitted to surgery, when the low and medium frequencies were analyzed, which demonstrates the positive impact of the surgical intervention on the tympano-ossicle system.(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Audiometria/métodos , Ossículos da Orelha/fisiopatologia , Orelha Média/fisiopatologia , Otosclerose/fisiopatologia , Testes de Impedância Acústica/métodos , Análise de Variância , Valores de Referência , Estatísticas não Paramétricas
4.
Bauru; s.n; 2015. 115 p. ilus, tab, graf.
Tese em Português | LILACS | ID: lil-756764

RESUMO

A avaliação da integridade do sistema tímpano-ossicular é um pré-requisito para que o processo de diagnóstico audiológico infantil possa ser concluído com precisão, assim, muito têm se discutido em relação aos procedimentos utilizados na prática clínica para definir a presença ou ausência de problema condutivo. Nesse sentido, as medidas de imitância acústica de banda larga mostram-se como uma opção para o avanço na área. Diante disso, surgiu o interesse em ampliar os conhecimentos e trazer as características das medidas de imitância acústica de banda larga nas diferentes condições de orelha média. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em crianças com perda auditiva sensorial de grau severo e profundo e diferentes padrões timpanométricos. Foram avaliadas 187 orelhas de 98 crianças na faixa etária de seis a 60 meses de idade, subdivididas em grupos de acordo com a pressão e compliância obtidas na timpanometria com sonda de 226 Hz. As medidas de imitância acústica de banda larga foram realizadas por meio do sistema de medidas do Acoustics' Middle-Ear Power Analyzer - MEPA, versão 5.0, utilizando os estímulos tom puro e chirp, com faixa de frequência de 211 a 6000 Hz. Os valores de compliância e pressão obtidos na timpanometria convencional foram correlacionados às medidas de imitância acústica de banda larga, adotando-se testes estatísticos apropriados, com nível de significância de 0,05. Os resultados obtidos evidenciaram o efeito das faixas de frequência (grave, média e aguda) em todas as medidas analisadas, com exceção do delay da reflectância. Foi constatada influência de pressões correspondentes a -100 daPa ou mais negativas e também para pressões positivas acima de 25 daPa, e compliâncias menores que 0,2 ml nas medidas de imitância acústica de banda larga. Além disso, houve diferença significante entre os estímulos tom puro e chirp para frequências baixas...


The evaluation of the integrity of the tympanic-ossicular system is a prerequisite for the child audiology diagnostic process to be completed accurately, thus, much has been discussed in relation to the procedures used in clinical practice to define the presence or absence of conductive problems. Hence, the wideband acoustic immittance measurements show to be an option to the advance in the field. As a result, the interest in expanding the knowledge and bringing the characteristics of wideband acoustic immittance measurements in the different conditions of middle ear, emerged. This study aimed at characterizing the wideband acoustic immittance measurements using pure and chirp stimuli in children presented with severe and profound sensorineural hearing loss and different tympanometric standards. 187 ears of 98 children in the age range six-sixty months, subdivided into groups according to pressure and compliance achieved through tympanometry with a 226 Hz probe, were assessed. Wideband acoustic immittance measurements were performed by the measuring system of the Acoustics' Middle-Ear Power Analyzer - MEPA, version 5.0, using pure and chirp tone stimuli, in a frequency ranging from 211 to 6000 Hz. The values of compliance and pressure obtained through conventional tympanometry were correlated with wideband acoustic immittance measures, by applying suitable statistical tests, with a 0.05 significance level. The results achieved evidenced the effect of frequency bands (low, medium and high) in all measures examined, with the exception of the reflectance delay. The Influence of pressures -100 daPa or more negative ones and also in positive pressures above 25 Pa, and compliance lower than 0.2 ml in the wideband acoustic immittance measurements, was verified. In addition, there was a significant difference between pure tone and chirp stimuli at low frequencies for impedance absorbance and magnitude, with a greater reflex of the variation of compliance...


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Estimulação Acústica/métodos , Perda Auditiva Neurossensorial/fisiopatologia , Testes de Impedância Acústica/métodos , Análise de Variância , Audiometria de Tons Puros/métodos , Valores de Referência , Índice de Gravidade de Doença
5.
Bauru; s.n; 2015. 115 p. ilus, tab, graf.
Tese em Português | LILACS, BBO | ID: biblio-867259

RESUMO

A avaliação da integridade do sistema tímpano-ossicular é um pré-requisito para que o processo de diagnóstico audiológico infantil possa ser concluído com precisão, assim, muito têm se discutido em relação aos procedimentos utilizados na prática clínica para definir a presença ou ausência de problema condutivo. Nesse sentido, as medidas de imitância acústica de banda larga mostram-se como uma opção para o avanço na área. Diante disso, surgiu o interesse em ampliar os conhecimentos e trazer as características das medidas de imitância acústica de banda larga nas diferentes condições de orelha média. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em crianças com perda auditiva sensorial de grau severo e profundo e diferentes padrões timpanométricos. Foram avaliadas 187 orelhas de 98 crianças na faixa etária de seis a 60 meses de idade, subdivididas em grupos de acordo com a pressão e compliância obtidas na timpanometria com sonda de 226 Hz. As medidas de imitância acústica de banda larga foram realizadas por meio do sistema de medidas do Acoustics' Middle-Ear Power Analyzer - MEPA, versão 5.0, utilizando os estímulos tom puro e chirp, com faixa de frequência de 211 a 6000 Hz. Os valores de compliância e pressão obtidos na timpanometria convencional foram correlacionados às medidas de imitância acústica de banda larga, adotando-se testes estatísticos apropriados, com nível de significância de 0,05. Os resultados obtidos evidenciaram o efeito das faixas de frequência (grave, média e aguda) em todas as medidas analisadas, com exceção do delay da reflectância. Foi constatada influência de pressões correspondentes a -100 daPa ou mais negativas e também para pressões positivas acima de 25 daPa, e compliâncias menores que 0,2 ml nas medidas de imitância acústica de banda larga. Além disso, houve diferença significante entre os estímulos tom puro e chirp para frequências baixas...


The evaluation of the integrity of the tympanic-ossicular system is a prerequisite for the child audiology diagnostic process to be completed accurately, thus, much has been discussed in relation to the procedures used in clinical practice to define the presence or absence of conductive problems. Hence, the wideband acoustic immittance measurements show to be an option to the advance in the field. As a result, the interest in expanding the knowledge and bringing the characteristics of wideband acoustic immittance measurements in the different conditions of middle ear, emerged. This study aimed at characterizing the wideband acoustic immittance measurements using pure and chirp stimuli in children presented with severe and profound sensorineural hearing loss and different tympanometric standards. 187 ears of 98 children in the age range six-sixty months, subdivided into groups according to pressure and compliance achieved through tympanometry with a 226 Hz probe, were assessed. Wideband acoustic immittance measurements were performed by the measuring system of the Acoustics' Middle-Ear Power Analyzer - MEPA, version 5.0, using pure and chirp tone stimuli, in a frequency ranging from 211 to 6000 Hz. The values of compliance and pressure obtained through conventional tympanometry were correlated with wideband acoustic immittance measures, by applying suitable statistical tests, with a 0.05 significance level. The results achieved evidenced the effect of frequency bands (low, medium and high) in all measures examined, with the exception of the reflectance delay. The Influence of pressures -100 daPa or more negative ones and also in positive pressures above 25 Pa, and compliance lower than 0.2 ml in the wideband acoustic immittance measurements, was verified. In addition, there was a significant difference between pure tone and chirp stimuli at low frequencies for impedance absorbance and magnitude, with a greater reflex of the variation of compliance...


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Estimulação Acústica/métodos , Perda Auditiva Neurossensorial/fisiopatologia , Testes de Impedância Acústica/métodos , Análise de Variância , Audiometria de Tons Puros/métodos , Valores de Referência , Índice de Gravidade de Doença
6.
Audiol., Commun. res ; 19(4): 421-425, Oct-Dec/2014. tab, graf
Artigo em Português | LILACS | ID: lil-732227

RESUMO

O objetivo deste trabalho foi analisar as medidas de reflectância em uma paciente com otosclerose. A paciente, do gênero feminino, 51 anos, apresentava queixa de hipoacusia bilateral e a hipótese diagnóstica de otosclerose. Foram realizados os seguintes testes de avaliação audiológica: imitanciometria, audiometria tonal, vocal e medidas de reflectância acústica, em ambas as orelhas. Por meio da análise dos resultados da reflectância acústica de banda larga, foi possível observar aumento na reflectância, característico de otosclerose, entre as frequências de 500 e 1500 Hz, e diferenciar a orelha esquerda e a orelha direita. As medidas de reflectância permitiram a obtenção de resultados detalhados por frequência que, em conjunto, possibilitaram a diferenciação entre as duas orelhas. O uso da reflectância de banda larga é sugerido para complementar o diagnóstico da otosclerose.


This research aimed to analyze the reflectance measurements in a patient with otosclerosis. The patient, female, 51 years old; she complained of bilateral hearing loss and had a diagnosis hypothesis of otosclerosis. The following audiological tests were performed in both ears: tympanometry, pure-tone audiometry, and speech audiometry tests and acoustic reflectance measurements. Through acoustic wideband reflectance analysis, it was possible to observe an increase in reflectance, such as is seen in otosclerotic ears, between the frequencies of 500 Hz and 1500 Hz and to differentiate the left and right ear. Acoustic reflectance measurements have the potential to yield results that allow the differentiation between the two ears; thus, the use of the wideband acoustic reflectance is suggested as a part of the otosclerosis diagnostic procedure.


Assuntos
Humanos , Feminino , Testes de Impedância Acústica/métodos , Audiometria , Perda Auditiva Bilateral/diagnóstico , Perda Auditiva/diagnóstico , Otosclerose/diagnóstico , Testes Auditivos/métodos
7.
Braz. j. otorhinolaryngol. (Impr.) ; 78(1): 95-102, jan.-fev. 2012. tab
Artigo em Português | LILACS | ID: lil-616943

RESUMO

Os objetivos deste estudo foram descrever e analisar as medidas timpanométricas obtidas com sonda de 226 e 1000 Hz; verificar correlação da timpanometria com o resultado das emissões otoacústicas e otoscopia; descrever as alterações. MATERIAL E MÉTODO: Estudo prospectivo, duplo cego, realizado com 70 bebês, entre 7 dias e 1 mês e 13 dias de vida. Foram realizadas as emissões otoacústicas, otoscopia e timpanometria com sonda de 226 Hz e 1000 Hz. RESULTADOS: Observou-se diferença estatisticamente significante (p<0,05) na correlação entre as medidas timpanométricas analisadas com os dois tons de sonda e na correlação entre o resultado das emissões otoacústicas e a compliância obtida. Foi observada normalidade em todos os exames na maioria dos bebês (94,28 por cento); apenas três (4,28 por cento) foram encaminhados ao diagnóstico audiológico e um bebê (1,42 por cento) apresentou alteração de orelha média confirmada pela otoscopia e timpanometria em 1000 Hz. CONCLUSÕES: A timpanometria realizada com tom sonda de 1000 Hz é a mais recomendada para avaliar bebês até 6 meses de idade. São necessários mais estudos com enfoque nas propriedades mecanoacústicas da orelha média de bebês para que a interpretação de exames com este tom de sonda tenha maior confiabilidade.


This study aimed at describing and analyzing tympanometric results obtained with 226Hz and 1000Hz probe tones; checking for correlations between tympanometry, otoacoustic emissions and otoscopic examination; describing abnormal results found in the evaluation procedures. METHODS: Double-blind and prospective study. Our sample included 70 babies, between 7 days and one month and 13 days of age, without risk indicators for hearing loss, evaluated in the State Neonatal Hearing Screening Program. Transient evoked otoacoustic emissions, otoscopic examination and tympanometry with 226Hz and 1000Hz probe tones were used as assessment tools. The study was approved by the Ethics Committee from the institution. RESULTS: Statistically significant differences were observed (p<0.05) in the tympanometric measures correlation and also between transient evoked otoacoustic emissions and compliance obtained with both probe tones. Most test results were within the normal range (94.28 percent). Three children (4.28 percent) were referred to diagnostic follow-up and one (1.42 percent) had middle ear dysfunction confirmed by otoscopy and 1000Hz tympanometry. CONCLUSIONS: 1000Hz tympanometry is the most reliable probe tone used to evaluate children under three months of age. More studies focusing on middle ear acoustics and mechanics are necessary to provide reliable and precise interpretation in the evaluation of middle ear functions in babies.


Assuntos
Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Testes de Impedância Acústica/métodos , Transtornos da Audição/diagnóstico , Emissões Otoacústicas Espontâneas/fisiologia , Método Duplo-Cego , Transtornos da Audição/fisiopatologia , Triagem Neonatal , Otoscopia , Estudos Prospectivos
8.
Rev. Assoc. Med. Bras. (1992) ; 57(3): 280-285, May-June 2011. tab
Artigo em Inglês | LILACS | ID: lil-591354

RESUMO

OBJECTIVE: The purpose of this study was to investigate the differences between P wave dispersion, aortic elastic properties and transthoracic echocardiographic findings in the young and old football players compared to control groups in order to asses the influence of regular sportive activity on aortic distensibility and its potential effect on atrial electrophysiology. METHODS : We recruited 42 young football players with a training history of many years. The control group was formed by 27 healthy sedentary men. Twenty-three healthy retired football players of a professional football club aged over 50 years were included in the study as old group and 18 subjects over 50 year old who did not perform regular exercise when they were young were included in the control group of old subjects. RESULTS: The heart rate and ejection fraction were decreased in the young football players. There were no significant differences in the aortic elastic parameters and P wave dispersion between young football players and control group. But in old subjects with sustained participation in regular sportive activity, the significant difference of left ventricular dimension, wall thickness and systolic functions detected in the young group disappeared while increase in the left atrial diameter became significant. CONCLUSION: Potential effect of aortic elastic properties which changes with age, on atrial electrophysiology through increasing P wave dispersion was shown.


OBJETIVO: Com este estudo pretendeu-se levar a cabo um ensaio clínico que permitisse investigar as diferenças entre a dispersão da onda P (DOP), as propriedades elásticas da aorta e os resultados da ecocardiografia transtorácica em futebolistas profissionais ativos e reformados, face a grupos de controle, de modo a avaliar a influência da atividade desportiva regular na distensibilidade aórtica e o seu potencial efeito na electrofisiologia atrial. MÉTODOS: Para este estudo foram recrutados 42 jovens futebolistas profissionais com um histórico de treino de vários anos. O grupo-controle foi constituído por 27 homens saudáveis e sedentários. No grupo composto por indivíduos mais velhos, foram incluídos 23 futebolistas profissionais já aposentados, saudáveis e com mais de 50 anos de idade e, como grupo-controle, 18 indivíduos com mais de 50 anos de idade que nunca fizeram qualquer tipo de exercício físico regular quando eram mais novos. RESULTADOS: A frequência cardíaca e fração de ejeção eram menores nos jovens futebolistas profissionais. Não se verificaram diferenças significativas nos parâmetros de elasticidade da aorta e a dispersão da onda P entre os jovens futebolistas profissionais e o grupo-controle. Mas, já no caso do grupo dos indivíduos mais velhos com uma atividade desportiva regular, a diferença significativa na dimensão ventricular esquerda, espessura das paredes e funções sistólicas detectada no grupo jovem e ativo desapareceu, enquanto o aumento no diâmetro atrial esquerdo tornou-se expressivo. CONCLUSÃO: Demonstrou-se com este estudo o efeito potencial das propriedades elásticas da aorta, que se alteram com a idade, na electrofisiologia atrial por meio do aumento da dispersão da onda P.


Assuntos
Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Aorta/fisiologia , Função do Átrio Esquerdo/fisiologia , Elasticidade/fisiologia , Futebol/fisiologia , Fatores Etários , Testes de Impedância Acústica/métodos , Pressão Sanguínea/fisiologia , Estudos de Casos e Controles , Ecocardiografia/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Comportamento Sedentário
9.
Rev. bras. otorrinolaringol ; 75(1): 80-89, jan.-fev. 2009. tab
Artigo em Inglês, Português | LILACS | ID: lil-514837

RESUMO

A avaliação audiológica do lactente deve ser composta pela verificação das condições de orelha média (medidas de imitância acústica e otoscopia) e pela avaliação coclear (Emissões Otoacústicas). OBJETIVO: Verificar qual tom teste da timpanometria (226Hz ou 1000Hz) tem maior correlação com o exame otoscópico e com o resultado das Emissões Otoacústicas por estímulo transiente. MÉTODO: Realizou-se emissões otoacústicas nos 60 lactentes da amostra, com idade entre de zero e quatro meses. Foram distribuídos em dois grupos, sendo o grupo I 30 lactentes com EOA presente e o grupo II 30 lactentes com EOA ausente. Foram submetidos à timpanometria de múltiplas freqüências, com tom teste de 226Hz e 1000Hz e avaliação otoscópica. RESULTADOS: Na timpanometria, o tom teste de 1000Hz apresentou mais sensibilidade para identificar as alterações de orelha média. Nas crianças com curva timpanométrica dentro da normalidade, ambos os tons-teste (226 e 1000Hz) apresentaram alta especificidade. Todas as correlações foram significantes com o tom teste de 1000Hz. CONCLUSÃO: O tom teste de 1000Hz apresentou maior correlação estatisticamente significante com as EOA e com a avaliação otoscópica para lactentes de zero a quatro meses.


Audiological evaluation in infants should include the middle ear (immitance measures and otoscopy) and also a cochlear evaluation. AIM: To check which tympanometry tone test (226 Hz or 1000 Hz), transient otoacoustic emissions and otoscopy. METHODS: Transient otoacoustic emissions were taken from sixty infants ranging from zero to four months of age. The babies were assigned to two groups of 30 infants each, according to the presence or absence of otoacoustic emissions (OAE). All babies have undergone tympanometry with probe tones of 226 and 1000 Hz and ENT evaluation. RESULTS: Tests performed with 1000 Hz probe tone were more sensitive in identifying middle ear disorders. In children with normal tympanograms, both probe tones (226 and 1000 Hz) showed high specificity. All correlations were significant when the 1000 Hz probe tone was used. CONCLUSION: The high frequency probe tone (1000 Hz) presented the most significant correlation with OAE and otoscopy in infants from zero to four months of age.


Assuntos
Humanos , Lactente , Recém-Nascido , Testes de Impedância Acústica/métodos , Transtornos da Audição/diagnóstico , Otoscopia , Emissões Otoacústicas Espontâneas/fisiologia , Estimulação Acústica , Transtornos da Audição/fisiopatologia , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Bulletin of Alexandria Faculty of Medicine. 2008; 44 (3): 653-662
em Inglês | IMEMR | ID: emr-101654

RESUMO

The present study was designed to formulate and modify a test to assess dyslexia in Arabic speaking children. The study works to establish its reliability and validity by comparing the performance of normal and dyslexic children, and hence providing a profile of strengths and weaknesses which can be used as a guide for the remedial program of these children. Forty dyslexic children and 120 normal children were subjected to thorough history taking, full clinical examination; including general examination, ear nose and throat examination, conventional neurological evaluation, ophthalmological and audiological evaluation, in addition to psychometric evaluation and language assessment. Formulation of the Arabic Dyslexia Assessment Test [ADAT] was done to suit Egyptian children. The test assessed the following items Rapid naming, Bead threading, One minute reading, Postural stability, Phonemic segmentation, Two minute spelling, backward digit span, Nonsense passage reading, One minute writing, Verbal fluency, and Semantic fluency. It was applied on normal and dyslexic children to test its validity and reliability. Test reliability was proven using test - retest method where the cases and the controls were retested 2 weeks from the original test date. Test validity was measured by Face validity and Construct validity. The results of the Arabic dyslexia assessment test were highly significant in discriminating dyslexics from non dyslexic children. The high validity and reliability of the formulated test proves the sensitivity and specificity of the test


Assuntos
Humanos , Masculino , Feminino , Criança , Acuidade Visual , Audiometria/métodos , Testes de Impedância Acústica/métodos , Psicometria/métodos , Reprodutibilidade dos Testes
11.
Bulletin of Alexandria Faculty of Medicine. 2008; 44 (4): 773-784
em Inglês | IMEMR | ID: emr-99560

RESUMO

Noise induced hearing loss is one of the most common and expensive sources of compensated work related health problems in modern industrialized countries. This study was conducted to detect the combined effect of occupational exposure to noise and lead on hearing. An observational analytic comparative approach was selected for this study. The inference population comprised 208 production workers from the Egyptian Copper Works Company in Alexandria, of these workers 51 were exposed to both noise and lead, 54 workers were exposed to noise, 53 workers were exposed to lead, and the rest, 50 workers were not exposed to neither noise or lead. All workers were subjected to a detailed interview, physical examination, otological examination, and auditory evaluation through a pure-tone audiometry, speech audiometry [Speech Reception Threshold [SRT] and Speech Discrimination Score [SDS]%], tympanometry, and auditory brain-stem response audiometry. Moreover, the blood lead level of workers, and workplace noise intensity were measured. Clinical evaluation of workers revealed a significant increase in mean systolic blood pressure among lead exposed and noise exposed workers. Neurological manifestations [tremors, tingling/numbness, reduced visual acuity and headache], urinary troubles, and oral manifestations gingivitis and bleeding gum], were significantly more encountered among lead exposed workers and workers with combined exposure. On assessing the workers' mean hearing threshold of the right ear, it was evident that at low frequencies [250 Hz and 500 Hz] the maximum significant drop was recorded among the workers with combined exposure [30.2 +/- 9.8 dB, 30.2 +/- 9.74 dB respectively], compared to lead exposed workers [29.15 +/- 8.42 dB, 28.49 +/- 6.97 dB respectively], and noise exposed workers [27.68 +/- 6.98 dB, 28.43 +/- 7.57 dB]. On the contrary, at higher frequencies [1 KHz - 8 KHz] the maximum drop was recorded by noise exposed worker. Regarding the left ear, the maximum impairment at low frequencies was observed among lead exposed workers [28.3 +/- 8.08 dB, 28.49 +/- 9.38 dB respectively], but at the higher frequencies a similar pattern to that observed at the right ear was obtained. Noise exposed workers had the most impaired mean SRT [31.48 +/- 8.22 dB], while workers with combined exposure recorded the worst mean SDS% [91.67 +/- 6.06%]. No significant delay was observed in the Auditory Brainstem Response [ABR] audiometry recorded at the latencies I, III, and V and inter-peak latencies; I-III, I-V, and III-V for the studied workers. On calculating the total hearing impairment percent, noise exposure imposed the worst effect on hearing, where both noise exposed workers and workers with combined exposure had the highest mean hearing impairment percent [15.25 +/- 13.61%, 13.22 +/- 13,49% respectively]. Among noise exposed workers, the significant predictors of hearing impairment were the duration of employment and smoking. While, blood lead level and aging were the significant predictors for hearing impairment among workers with combined exposure. Cochlear affection is the main site of lesion in noise and/or lead exposed workers, and the risk of combined exposure to noise and lead imposed on the auditory system sensitivity at the studied levels of exposure is nearly similar to that encountered by noise exposure alone


Assuntos
Humanos , Chumbo/efeitos adversos , Chumbo/sangue , Perda Auditiva Provocada por Ruído/etiologia , Audiometria/métodos , Potenciais Evocados Auditivos do Tronco Encefálico , Testes de Impedância Acústica/métodos
12.
Rev. bras. otorrinolaringol ; 73(5): 633-639, ago.-out. 2007. tab
Artigo em Inglês, Português | LILACS | ID: lil-470444

RESUMO

Timpanometria avalia condições funcionais da orelha média. Quando realizada em neonatos abaixo de quatro meses de idade pode gerar dúvidas. Sondas de alta freqüência têm sido investigadas na busca por resultados mais confiáveis. OBJETIVO: Descrever e analisar interpretações de características e medidas obtidas na timpanometria em neonatos com freqüências de 226, 678 e 1000Hz. MATERIAL E MÉTODO: Os 110 neonatos avaliados tinham idade entre 6 e 30 dias, não apresentaram fatores de risco e tinham emissões otoacústicas presentes. A timpanometria foi realizada com o analisador GSI-33-II, na Divisão de Educação e Reabilitação dos Distúrbios da Comunicação, São Paulo, em 2004. FORMA DE ESTUDO: Clínico prospectivo. RESULTADOS: Observou-se equilíbrio nas curvas pico único e pico duplo em 226Hz, maior ocorrência de assimétrica em 678Hz e de pico único em 1000 Hz. Houve significância de gênero na medida volume equivalente do meato acústico externo, em 226Hz, e na medida admitância acústica estática de pico compensado, em 1000Hz. O protocolo inglês apresentou quase 100 por cento de normalidade em 678 e 1000Hz. CONCLUSÃO: A sonda de 1000Hz apresentou melhores resultados na caracterização da normalidade. O protocolo inglês mostrou-se eficiente em diminuir variabilidades das medidas. Os resultados podem ser usados como guia no diagnóstico da timpanometria.


Tympanometry is used in evaluating middle ear functional conditions. Before six months of age its results may be misleading. High frequency studies aim to provide more valid procedures. AIM: To describe and discuss tympanometric measurements and the interpretation in normal hearing neonates at 226, 678 and 1000Hz. METHOD: 110 neonates that were analyzed had normal otoacoustic emissions and no risk for hearing impairment. The age range was 6 to 30 days. Curves were obtained using the GSI-33-II, at the Divisão de Educação e Reabilitação dos Distúrbios da Comunicação, São Paulo, in 2004. STUDY DESIGN: Clinical prospective. RESULTS: There was a balance between single and double peak curves at 226Hz. Most of the curves were asymmetric at 678Hz, and single-peaked at 1000Hz. quantitative measurements showed a significant gender difference in the Equivalent Ear Canal Volume at 226Hz and on the Peak Compensated Static Acoustic Admittance at 1000Hz. The English protocol showed that almost 100 percent of ears were normal at 678 and 1000Hz. CONCLUSION: 1000Hz yielded superior results for characterizing normality. The English protocol was efficient to reduce the variability of tympanometric measurements. Data from this study may be used as a guide for diagnosis using tympanometry in neonates.


Assuntos
Feminino , Humanos , Recém-Nascido , Masculino , Testes de Impedância Acústica/métodos , Estimulação Acústica/métodos , Orelha Média/fisiologia , Triagem Neonatal/métodos , Emissões Otoacústicas Espontâneas/fisiologia , Estudos Prospectivos , Valores de Referência
13.
Rev. bras. otorrinolaringol ; 72(6): 836-844, nov.-dez. 2006. tab
Artigo em Português | LILACS | ID: lil-441141

RESUMO

Algumas drogas, denominadas ototóxicas, têm a capacidade de lesar os sistemas auditivo e vestibular. O avanço tecnológico tem disponibilizado inúmeros recursos para realizar o monitoramento da audição, porém, apesar da disponibilização de protocolos de avaliação internacionais, existem controvérsias quanto à escolha do procedimento de maior sensibilidade e especificidade para este fim. OBJETIVO: Analisar os procedimentos audiológicos utilizados no monitoramento auditivo dos indivíduos expostos à medicação ototóxica. METODOLOGIA: Realizou-se busca eletrônica nas bases de dados MEDLINE e LILACS, a partir da combinação entre os descritores que caracterizaram as temáticas monitoramento auditivo, ototoxicidade e câncer. A literatura apontou dois principais procedimentos efetivos no monitoramento: a audiometria de altas freqüências e as emissões otoacústicas. Ambos permitem que a alteração no sistema auditivo seja identificada antes que haja um comprometimento dos limiares tonais na faixa de freqüências convencional, e conseqüentemente na habilidade de compreensão da fala. CONCLUSÃO: O protocolo de monitoramento auditivo foi sugerido considerando a capacidade do paciente em responder aos testes comportamentais e a etapa do monitoramento (primeira avaliação ou subseqüentes). No caso de portadores de câncer, o monitoramento auditivo deve ser disponibilizado no local de tratamento do indivíduo.


Some pharmaceutical products are capable of damaging the human auditory system. Technological progress has provided numerous resources to monitor hearing but there still is some controversy regarding the selection of the most sensitive and specific tests. OBJECTIVE: to analyze audiological procedures used in the auditory monitoring of individuals exposed to ototoxic medication. METHODS: we searched the MEDLINE and LILACS literature databases, using terms pertinent to audiological monitoring, ototoxicity and cancer. The pertaining literature analysis identified two procedures often used worldwide for the early detection of auditory lesions induced by ototoxic pharmaceutical drugs: high-frequency audiometry and evoked otoacoustic emissions. Both allow early identification of hearing disorders before changes are seen in conventional pure-tone audiometry and, consequently, before speech understanding is compromised. CONCLUSION: we suggest a hearing monitoring protocol, considering the patientÆs capability to respond to behavioral tests and monitoring timing (first test/follow up). For cancer patients, hearing monitoring should be performed in the patientÆs treatment venue.


Assuntos
Adulto , Criança , Humanos , Perda Auditiva/induzido quimicamente , Perda Auditiva/diagnóstico , Audiometria de Tons Puros , Testes de Impedância Acústica/métodos , Potenciais Evocados Auditivos do Tronco Encefálico
14.
Rev. Méd. Clín. Condes ; 17(1): 20-25, Ene. 2006. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-428668

RESUMO

La efusión el oído medio es una de las patologías más frecuentes en pediatría, y requiere para su diagnóstico la confirmación de líquido en el oído. La timpanometría es el método objetivo más usado para confirmar efusión en el oído medio cuando la otoscopía es dudosa o alterada. La reflectometría acústica es un nuevo método que ofrece las ventajas de ser portátil, indoloro y de fácil manejo. Se estudiaron 104 niños entre seis meses y 18 años, a los que se les realizó timpanometría y reflectometría acústica con un total de 204 oídos evaluados, considerando como riesgo de efusión en el oído medio valores de ángulo de gradiente espectral entre 0 y 64º. Al comparar la reflectometría con la timpanometría (prueba estándar) se observó una especificidad de 99 por ciento, una sensibilidad de 57 por ciento, un valor predictivo positivo de 97 por ciento y un valor predictivo negativo de 75 por ciento. Estos resultados nos permiten recomendar a la reflectometría acústica como método objetivo para descartar con alta seguridad la presencia de líquido en el oído medio. Por sus ventajas sugerimos su implementación y utilización masiva en la población pediátrica, lo que ayudaría a un manejo más expedito y adecuado de la otitis media secretora.


Assuntos
Masculino , Adolescente , Humanos , Feminino , Lactente , Pré-Escolar , Criança , Otite Média com Derrame/diagnóstico , Testes de Impedância Acústica/instrumentação , Testes de Impedância Acústica/métodos , Sensibilidade e Especificidade
15.
São Paulo; s.n; 2004. [248] p. ilus, mapas, tab, graf.
Tese em Português | LILACS | ID: lil-405086

RESUMO

Objetivo: este estudo teve por objetivo verificar a eficácia de um procedimento para a identificação da deficiência auditiva em crianças pré escolares de uma comunidade de baixa renda por pessoas não especialistas. Casuística e métodos: funcionários da creche e da unidade de saúde foram treinados para aplicarem um questionário para triagem auditiva nos pais de 224 crianças de 3 a 6 anos de idade, que foram submetidas à triagem audiométrica e imitanciométrica. Resultados: verificou-se alta concordância na coleta de dados por meio do questionário entre a pesquisadora e os não especialistas. O questionário apresentou melhor sensibilidade e pior especificidade. Os não especialistas relataram aprendizado com a pesquisa e conscientização sobre a importância da audição. Conclusão: é possível treinar agentes comunitários a identificarem a deficiência auditiva em suas comunidades com instrumentos de baixo custo./Preschool children’s hearing loss detection: Low cost action plan in a poor community Aim: this study aimed to access the efficacy of a low cost instrument used by non professionals to identify hearing loss in pre-school children in a low income community. Methods: employees of a nursery school and a health unit were trained to use a hearing screening questionnaire with parents of 224 children aged 3 to 6 years. The children underwent audiological screening. Results: the results showed that the non - specialists were capable of reproducing the evaluation of the professional regarding the use of the questionnaire. The questionnaire presented better sensitivity than specificity. The non – specialists reported learning and awareness of the importance of hearing in children. Conclusion: the questionnaire offers a low cost option for hearing screening, specially if it is administered by non professionals resources...


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Centros Comunitários de Saúde , Creches , Testes de Impedância Acústica/métodos , Pré-Escolar , Estudos Transversais , Eficácia , Pessoas com Deficiência Auditiva/educação , Pessoas com Deficiência Auditiva/estatística & dados numéricos , População Suburbana , Inquéritos e Questionários , Triagem
16.
Arq. bras. endocrinol. metab ; 47(1): 82-86, fev. 2003. tab
Artigo em Português | LILACS | ID: lil-336080

RESUMO

A presença de sintomas otológicos associados ao diabetes mellitus (DM) é discutida há seis décadas; entretanto, sua etiologia ainda permanece obscura. Uma vez que a associação entre perda auditiva e DM é ainda bastante controversa na literatura mundial, neste estudo realizou-se uma análise comparativa entre a presença de queixa e perda auditiva em pacientes com DM. Foram estudados 552 anamneses e 36 indivíduos com e 36 sem DM (grupo controle) através de audiometria tonal limiar e imitância acústica. A acuidade auditiva em 97,2 por cento dos pacientes com DM mostrou-se neurossensorial com rebaixamento nas agudas. Conclui-se haver associação direta entre DM e perdas auditivas, principalmete nas freqüências agudas.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 2/diagnóstico , Perda Auditiva Neurossensorial , Idoso de 80 Anos ou mais , Audiometria , Tontura , Anamnese , Testes de Impedância Acústica/métodos , Zumbido
18.
Acta AWHO ; 21(3/4)jul.-dez. 2002. tab, graf
Artigo em Português | LILACS | ID: lil-350211

RESUMO

Objetivo: comparar os escores do reconhecimento de fonemas em situação de silêncio e na presença de ruído competitivo (ruído branco, relação sinal/ruído de +10dB). Método: cinco crianças em idade escolar com deficiência auditiva neurossensorial pós-lingual de grau moderado até severo foram testadas utilizando um aparelho de amplificação sonora individual (AASI) analógico e um aparelho de amplificação sonora individual híbrido com múltipla memória e múltiplos canais. Resultados: não houve diferença entre os escores obtidos com a utilização do aparelho de amplificação sonora individual analógico e os obtidos com o aparelho de amplificação sonora individual híbrido, nas diferentes programações, para ambas situações avaliadas. Conclusão: na amostra avaliada recursos como a múltipla memória e compressão multicanal não melhoraram a performance de reconhecimento de fala no silêncio e na presença de ruído.


Assuntos
Humanos , Masculino , Feminino , Criança , Auxiliares de Audição , Perda Auditiva Neurossensorial , Audiometria , Limiar Auditivo , Percepção Sonora , Discriminação da Altura Tonal/fisiologia , Testes de Impedância Acústica/métodos
19.
Acta AWHO ; 21(3/4)jul.-dez. 2002. ilus, tab
Artigo em Português | LILACS | ID: lil-350214

RESUMO

Objetivo: Método: Resultados: Conclusão: Realizamos um estudo sobre os efeitos das variações na posição de colocação do fone TDH escrever por extenso 39 junto à orelha externa e suas influências na percepção fisiológica do som, colocação dos fones evita intercorrências clínicas indesejáveis, como o colabamento do meato acústico externo, que comprometem o diagnóstico audiológico.


Assuntos
Humanos , Masculino , Audiologia , Audiometria de Tons Puros , Orelha Externa , Auxiliares de Audição , Transtornos da Audição , Testes de Impedância Acústica/métodos , Limiar Auditivo , Meato Acústico Externo
20.
Acta AWHO ; 21(3/4)jul.-dez. 2002. tab, graf
Artigo em Português | LILACS | ID: lil-350215

RESUMO

Objetivo: Estabelecer o perfil audiológico de indivíduos com HIV. Método: Os exames otorrinolaringológico e audiológico foram realizados em 14 indivíduos entre três meses e oito anos de idade, todos HIV positivos. Resultados: Foram encontrados cinco casos de surdez condutiva. Conclusão: Não encontramos perdas auditivas neuro-sensoriais neste grupo de pacientes.


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Criança , Audiometria de Tons Puros , Audiometria da Fala , HIV-1 , Testes de Impedância Acústica/métodos , Perda Auditiva Condutiva